S20A108 User's Guide - Rev. A02 StorCase Technology, Inc.
Installation 11
5. Adjust the front of the receiving frame so the carrier slides freely in and out on
the receiving frame guides. The position of adjoining peripheral units may require
adjustment
NOTE: Option Pins 13-16 (Table 2) are used to remotely access the disk drive's
motor control options. Refer to the documentation provided by the drive
manufacturer for further information.
Table 2: Option Pins 13-16 Drive Motor Control
Open Open Motor spins up on "Power On"
Open Closed Motor spins up only if SCSI
"Start" command is received
Closed Open Drive motor starts spinning up
approximately 12 seconds x the
SCSI ID number for each target
drive (12 second minimum)
Closed Closed Reserved
Closed = Jumper installed
Open = Jumper removed
DYST RMST Function